-
Optical Bandpass Filter
-
Fluorescence Bandpass Filter
-
IR Bandpass Filter
-
UV Bandpass Filter
-
ITO Electromagnetic Shielding Glass
-
Biochemistry Analyzer Filters
-
Visible Bandpass Filter
-
Long Pass Optical Filter
-
Short Pass Optical Filter
-
Anti Reflection Filter
-
High Reflective Film
-
Optical Beam Splitter
-
Anti Glare Goggles
Kingki Uv Short Pass Filter 250nm for hot mirrors minimize unwanted heat
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xPlace Of Origin | Beijing, China | Brand Name | Kingki |
---|---|---|---|
Product Name | 250nm Short-wave Pass Filter | Substrate | Clear Optical Glass |
Half Wavelength | 250nm | Working Wavelength | 200-245nm |
Transmittance | 50% | Application | Medical Detection Instruments |
Size | 40*1.1mm | Customized | OEM |
High Light | uv short pass filter 250nm,uv short pass filter Hot Mirrors,Kingki uv shortpass filter |
Center wavelength | Working wavelength | Tamx | Cut-off | Size | Quantity | |
---|---|---|---|---|---|---|
250nm | 200-245nm | 50% | 200-1100nm | 40*1.1mm | Custom |
High Transmittance 250nm Short-wave Pass Filter
Shortpass Edge and Dichroic Filters are used to transmit wavelengths shorter than the cut-off wavelength of the filter. Shortpass Edge and Dichroic Filters are commonly use in life science applications including fluorescence microscopy or for integration into a variety of instrumentation. Shortpass Filters are typically designed for a 0° Angle of Incidence, whereas Shortpass Dichroic Filters are designed for use at a 45° Angle of Incidence. Shortpass Edge and Dichroic Filters can be used with Longpass Edge and Dichroic Filters to create custom bandpass filters to selectively transmit portions of the spectrum while rejecting all other wavelengths. These optical filters can also be used as hot mirrors to minimize unwanted heat caused by infrared radiation.
Short Wave Pass Filter | |||||||
Application | Half Wavelength(nm) | Transmission wavelength(nm) | Transmitt ance | blocking wavelength(nm) | Transmitt ance | Type | |
Short Wave Pass Filter | Industrial camera 650 | 650 | 400-620 | >50 | 700-110o | ≤1% | KK一SP650 |
ir-cut 650 | 650 | 400-630 | ≥90% | 670-1100 | <1% | ir-cut650 | |
ir-cut 670 | 670 | 400-650 | ≥90% | 690-1100 | <1% | ir-cut670 | |
ir-cut 690 | 690 | 400-66o | ≥90% | 710-1100 | <1% | ir-cut690 | |
ir-cut 710 | 710 | 400-670 | ≥90% | 730-1100 | <1% | ir-cut710 | |
CDimaging 620 | 620 | 400-600 | ≥90% | 700-1100 | <5% | KK-BC620 | |
CDimaging 650 | 650 | 400-620 | ≥90% | 700-1100 | <5% | KK-BG620 | |
Night vision 8o0 | 800 | 400-760 | ≥90% | 830-1100 | <1% | KK-SP800 | |
infrared reflectance 780 | 780 | 400-740 | ≥90% | 810-1100 | 之1% | KK-SP780 | |
Analysis instrument 707 | 706.5 | 400-686 | ≥90% | 726-1100 | ≤1% | KK-SP706 | |
laser 730 | 730 | 400-710 | ≥90% | 750-1100 | ≤1% | KK-SP730 | |
laser 750 | 750 | 400-730 | ≥90% | 770-1100 | ≤1% | KK-SP750 | |
Analysis instrument 767 | 766.5 | 400-746 | ≥90% | 786-1100 | ≤1% | KK-SP766 | |
Analysis instrument 795 | 794.7 | 400-775 | ≥90% | 815-1100 | ≤1% | KK-SP795 | |
laser 780 | 780 | 400-760 | ≥90% | 800-1100 | ≤1% | KK-SP780 | |
laser 830 | 830 | 400-810 | ≥90% | 850-1100 | ≤1% | KK-SP830 |